Interactive viewer
Improvement of Microangiopathy in Anti-Mi2 Dermatomyositis After Immunosuppressive Treatment
Images & measurements56The study, field by field
Images & measurements
Explore the fields from each finger and open any image for a closer look. Measurements describe the complete examination at each visit.
Contributed by Luis Peñaranda Bolaño, MD for educational publication on Capillaroscopy.com. For reuse permissions, contact the rights holder.
Initial study at diagnosis
Active severe microangiopathy before treatment
Recorded measurements
- Capillary density
- 3.26capillaries/mm
- Enlarged capillaries
- 57.61%
- Giant capillaries
- 27.17%
- Hemorrhages
- 1.24/mm
Values from the saved analysis: density and hemorrhages per total analyzed length; percentages of the total capillary count. These are not measurements of an individual image and may differ from averages across fields.
Left index finger
3 imagesLeft middle finger
2 imagesLeft ring finger
3 imagesRight middle finger
4 imagesRight ring finger
6 images
Nailfold capillaroscopy: right ring finger, field 19.

Nailfold capillaroscopy: right ring finger, field 20.

Nailfold capillaroscopy: right ring finger, field 21.

Nailfold capillaroscopy: right ring finger, field 22.

Nailfold capillaroscopy: right ring finger, field 23.

Nailfold capillaroscopy: right ring finger, field 24.
Right little finger
7 images
Nailfold capillaroscopy: right little finger, field 25.

Nailfold capillaroscopy: right little finger, field 26.

Nailfold capillaroscopy: right little finger, field 28.

Nailfold capillaroscopy: right little finger, field 29.

Nailfold capillaroscopy: right little finger, field 30.

Nailfold capillaroscopy: right little finger, field 31.

Nailfold capillaroscopy: right little finger, field 32.
Follow-up study 1 year after treatment
1 year after the initial study
Improved non-specific pattern after treatment
Recorded measurements
- Capillary density
- 6.84capillaries/mm
- Enlarged capillaries
- 12.66%
- Giant capillaries
- 0.00%
- Hemorrhages
- 0.02/mm
Values from the saved analysis: density and hemorrhages per total analyzed length; percentages of the total capillary count. These are not measurements of an individual image and may differ from averages across fields.
Left index finger
4 imagesLeft middle finger
4 imagesLeft ring finger
4 imagesLeft little finger
3 imagesRight index finger
3 imagesRight middle finger
4 imagesRight ring finger
5 images
Nailfold capillaroscopy: right ring finger, field 23.

Nailfold capillaroscopy: right ring finger, field 24.

Nailfold capillaroscopy: right ring finger, field 25.

Nailfold capillaroscopy: right ring finger, field 26.

Nailfold capillaroscopy: right ring finger, field 27.